XC-623 Series Console

Manual Sampling of Gaseous Pollutants

Overview

The Apex Instruments XC-623 Series Console is a versatile and dependable manual gas sampling unit designed for collecting gaseous pollutants from stationary sources such as stacks, flues, vents, and pipes.

This console is commonly used for EPA Methods 6, 26, and VOST (Methods 0030 & 0031) but is also suitable for other methods requiring precise volume measurements and constant sample flow rates between 300 ccm to 4 LPM.

Key Features & Specifications

  • Three advanced, self-tuning 1/32 DIN temperature controllers with solid-state relays
  • User-friendly 4-button keypad to reset gas volume and elapsed time at the start of each sample period
  • Rugged and lightweight roto-moulded polyethylene case with three stainless-steel carrying handles
  • Compatible with multiple EPA Methods, including:
    • Method 4 – Determination of Moisture Content
    • Method 6 & 6A – Measurement of Sulphur Dioxide (SO₂)
    • Method 26 – Measurement of Hydrogen Halides & Halogens
    • Method 0030 (VOST) – Measurement of Volatile Organic Compounds (VOCs)

Technical Specifications

  • Dry Gas Meter:
    • Model SK25EX, multi-chamber positive displacement meter
    • Accuracy ±1.5% at volumes greater than 10 litres
    • 0.7L cyclic volume, 400 pulses per revolution
    • Type-K thermocouple for exit temperature
  • Display:
    • 4×20 character backlit transflective LCD display
    • Viewing area: 74 mm × 45 mm
    • Operating temperature: -20°C to 70°C
  • Flow Measurement:
    • Precision stainless-steel venturi orifice with pressure transducer
    • Range: 0-5 inH₂O (0-1245 Pa) with 0.01 inH₂O (1 Pa) resolution
  • Internal Sample Pump:
    • Dual-head diaphragm pump, 8.0 LPM free flow
    • Max vacuum: 23 inHg (-230 mbar abs.)
    • 12V DC brushless motor
  • Temperature Measurement:
    • Cold junction-compensated Type-K thermocouple-to-digital converter
    • Selectable °C/°F range: -200°C to 1372°C (-328°F to 2502°F)
    • 6-channel rotary switch (supports up to 5 additional Type-K thermocouple inputs)
  • Temperature Controllers (Probe, Filter, Auxiliary):
    • Fuji PXR3 compact 1/32 DIN self-tuning PID temperature controller
    • Solid-state relay (25-amp driver), Type-K thermocouple input
  • DGM Pressure Sensor:
    • High-resolution digital sensor, factory-calibrated
    • Range: ±5.0 inH₂O (±1245 Pa) with 0.001 inH₂O (1 Pa) resolution
    • Accuracy: Better than ±0.25%
  • Umbilical Connections:
    • Sample inlet: 1/4-inch stainless-steel quick connect
    • Pitot lines: 1/4-inch stainless-steel quick connect
    • Electrical: Multi-conductor circular connector
    • Thermocouple inputs: Auxiliary, stack, probe, oven, and exit
  • Power Supply:
    • 120V AC at 60Hz (15A max)
    • 240V AC at 50Hz (10A max) (optional)
  • Dimensions: H17” × W17” × D12” (43 cm × 43 cm × 30.5 cm)
  • Weight: 29.6 lbs (13.4 kg)

A Versatile and Dependable Gas Sampler The XC-623 Series Console offers accurate and reliable gas sampling for a wide range of environmental and compliance applications.